Purge and Trap using the 7300 Autosampler
Purge & Trap
CDS 7350
Product Introduction
Specifications:
Sample Positions:
Sampling Volume:
Internal Standard:
Sample Pathway:
Water Mode:
Soil Mode:
Placement Accuracy
(3D):
Height:
Width:
Depth:
Weight:
​
72
5 ml/25 ml
2 µl
PEEK
Yes
No
​
1 mm
48.2 cm
56.9 cm
62.2 cm
23 kg
Summary
The 7350 autosampler is a competitively priced, 72 position autosampler for EPA methods 524, 624 and 8260 waters, and built on our 2nd generation autosampler with a more precise handling for sample loading. A perfect match for the 7000 Purge & Trap concentrator.
Product Features
72 Position Autosampler
The autosampler comes with a high capacity of 72 positions for 40 ml VOC vials in three separated racks.
Internal Standard Addition
CDS purge and trap autosampler adopts a unique 10 port valve with micro-loop technology to precisely inject 2 micro liter of internal standard into the sample, which guarantees the RSDs under 3%.
5 mL and 10 mL Sample Loop
Depending on the sample size from the Purge and Trap concentrator, the autosampler could accommodate both 5 mL (default) and 25 mL (optional) sample transfer.
Precision Robotic Arm
The position accuracy of the 2nd generation autosampler is improved by 50% to 1 mm (X, Y and Z) 3D placement accuracy due to a high precision drive mechanism
Ease of Alignment
The alignment calibration has been significantly improved in the 2nd generation autosampler. The user friendly software tool helps make alignment calibration in under 10 minutes.
Longer Life Expectancy
The 2nd generation autosampler comes with a SMART acceleration control to lower the impact on the driving mechanism by 40%. This extends the life of the system due to less strains.
PEEK Sample Pathway
​
The chemically inert sample pathway guarantees the success of your purge and trap testing even with challenging liquid samples.
Powerful and User-Friendly PC Interface
The PC software has a friendly interface to configure each run with programmable rinses, programmable blanks and internal standard addition.
Multiple Aliquots
​
The sampling double-jacketed needle could be configured to reach the bottom of the VOC vial to perform multiple aliquots runs from the same sample.
Applications
Parts&Options | Description | Part Number |
---|---|---|
Instrument | 7350 Autosampler waters only - 72 sample positions | 7350-5001 |
Option | Chiller Tray Option (requires re-circulation Chiller) for 7350/7450 | 7074-4039 |
Option | Automatic switching loop 5 ml and 25ml for 7450/7350 autosampler | 7071-5120 |
Option | Sample Loop 25ml | 2460-0340 |
Parts | 5 ml Fritted Vessel with Sidearm for Purge & Trap Autosampler | 1010-0493 |
Parts | Vial Septa 22mm for 40ml Vials (72 each) | 1010-0499 |
Parts | 25 ml Fritted Vessel with Sidearm for Purge & Trap Autosampler | 1010-0509 |
Parts | Water Inner Needle | 1010-0505 |
Parts | Vial - Clear Vial/Septa 40ml (72 each) | 1010-0497 |
Downloads
Request form for manuals and software
Purge & Trap Series