Search Results
Search this site
545 results found with an empty search
Other Pages (123)
- CDS Analytical | Pyrolyzer | Photoprobe
CDS's Photoprobe provides the easiest way to perform weather-induced polymer degredation studies. Home >> Products >> Pyrolysis >> Photoprobe Pyrolysis Introduction Features Applications Parts & Options Downloads Photoprobe Product Introduction Specifications: Wavelength: Light Intensity: Light Control: Compatibility : Weight: Dimension (W x H x D): Options: 260 - 400 nm 800 mW/mm2 0-100% (1% step) 6150, 6200 with Autosampler 1 kg 4" X 5" X 3" Calibration Sensor Summary The CDS Photoprobe is a unique device that uses high power xenon lamp to irradiate sample in the Drop In Sample Chamber (DISC) to introduce environmental degradation with the combination of programmable temperature and user-select reactant gas. The intensity of the UV light is 100 times stronger than any competitor’s product, which shortens the testing time from hours to minutes. Product Features High Power Xenon Lamp A high power Xenon lamp provides an intense point source and high brightness with only 1 minute stabilization time and over 1000 hours lamp life time. Free Space Focusing The light from the light source is focused on the sample through a series of condenser lens without using any optical fiber, which dramatically improves the max light density. 260 nm - 400 nm Wavelength A series of optical filters are used to block light with wavelength above 400 nm to prevent sample heating from absorbing IR light. Easy Installation The Photoprobe is designed to be mounted inside the 6000 Autosampler module. The installation takes minutes to complete. UV Light Safety Due to the levels of UV radiation from the Photoprobe, ensure necessary safety equipment such as UV protective eyewear and sufficient vent in the lab for UV generated ozone. Software Compatible The 6000 series software has embeded the Photoprobe control option in the autosmapler module. Product Introduction Product Features Applications 219Weather-Induced Degradation Study of Polystyrene Using the Photoprobe Reproducibility data on a rapid, automated polymer degradation study under ultraviolet (UV) light with the presence of oxygen. 6000 6200... Applications Parts & Options Options Description SKU CDS Photoprobe UV Light Module for DISC with Short-arc Xenon Lamp 6204-5060 Photoprobe Calibration Sensor 6204-5061 Please reload Parts & Options Downloads Marketing Brochures CDS Pyroprobe Brochure Request form for manuals and software Thanks for contacting CDS! Our specialist will contact you soon. Send Downloads Pyroprobe Series CDS 4000 CDS's most cost effective single temperature Pyroprobe. Read More CDS 6200 CDS's 6th Generation Pyroprobe with trapping capabilities for reactant gas apps. Read More DISC Module CDS's DISC module provides the easiest way to load your pyroloysis sample. Read More CDS 6150 CDS's 6th Generation Pyroprobe with up to 10 programmed temperature steps. Read More CDS 6400 CDS's 6th Generation Pyroprobe with up to 10 programmed temperature steps and large volume samples. Read More Autosampler Module CDS's autosampler module with Dynamic Loading to improve productivity for any 6000 series pyroprobe. Read More CDS HPR CDS's HPR Pyroprobe allows pyrolysis at elevated pressure with built-in reactor. Read More Photoprobe Photoprobe is a device that irradiates sample in the Drop In Sample Chamber with high intensity UV light Read More Cryo-mill CDS's cryo-mill is a laboratory ball mill that grinds polymer sample in liquid nitrogen temperature. Read More Microplastics Standards Mixed microplastics standards with options prepared according to ASTM Method 8401-24. Read More MSChrom Py-GC-MS Database Powerful Py-GC-MS data processing software and database Read More
- CDS Analytical | Pyrolyzer | HPR
CDS's high pressure pyrolyzer with reactor option to provide pilot study for plastic recycling or biomass fuel by Pyrolysis - Gas Chromatography - Mass Spectrometry (Py-GC-MS). Home >> Products >> Pyrolysis >> CDS HPR Pyrolysis Introduction Features Applications Parts & Options Downloads CDS 5200 HPR Product Introduction Product Features CDS Resistively Heated Filament The CDS resistive heating coil is the most versatile way to pyrolyze your sample with the lowest thermal mass and quickest temperature ramp up rate. Pyrolysis in Extreme Enviroments The CDS HPR enables you to carry out pyrolysis at an elevated pressure of 500 PSI. No other systems can even come close. User Selectable Catalyst Reactor The CDS HPR system comes with a reactor system to enable catalysis studies at max temperature of 800 °C . The reactor can be bypassed through the rotation of a valve. Digital Display of the Pressure and Temperature No more guess on the sample pressure, and no more mess to crash the pyrolysis tube. The pressure and temperature are accurately and digitally controlled and displayed. Heavy Duty Back Pressure Regulator The back pressure regulator is the most heavy duty regulator commercially available. It reliably handle the most challenging settings. Optional Steam Module The optional steam module allows the user to carry out pyrolysis with steam as a reactant gas by elevated pressure. This option is another CDS first in advance pyrolysis capabilities. Product Features Product Introduction Specifications: Programmable Time: Trap: Temperature Range: Temperature Accuracy: Heating Rate: Probe Clean: Probe Dry: System Max Pressure: Reactor Max Temperature: Catalyst Volume: Interface Type: Interface Temperature: Interface Heating Rate: GC Connection: Weight: Dimension (W x H x D): Options: 0 - 999.9 minutes Yes, Standard Tenax-TA Cryotrap available Up to 1400°C 1°C 0.01°C/ms to 20°C/ms 0.01°C/sec to 999.9°C/sec 0.01°C/min to 999.9°C/min Yes. User-selectable. Yes. User-selectable. 500 PSI (3.4 MPa) 800°C 6 mm X 75 mm (2 ml total volume) Low Thermal Mass Up to 350°C 1°C/min to 100°C/min Heated Transfer line (up to 350°C) 25 kg 280 mm X 670 mm X 480 mm Steam, Cryotrap Summary The CDS HPR Pyroprobe enables users to study both high temperature and pressure in a micro-scale environment, with the convenience of results sent directly to their GC/MS for Pyrolysis - Gas Chromatography - Mass Spectrometry (Py-GC-MS) . The unit is built on 5200 platform with a backpressure regulator and heated catalyst bed. Samples can be pyrolyzed at max 500 PSI (3400 kPa), passed through a user-selectable catalyst bed, and collected onto the built-in trap. Applications 136a Pyrolysis-Catalytic Hydrogenation of Vegetable Oil Reactor High Pressure Reactor Pyroprobe Pyrolysis Energy Food and Flavor HPR 5200HPR Click to Download 129a Hydrogenation of Crude Oil at Elevated Pressure 5200HPR High Pressure Reactor Pyroprobe Pyrolysis Energy Click to Download 130a Pyrolysis of Oil Shale in Hydrogen at Elevated Pressure 5200HPR High Pressure Reactor Pyrolysis Pyroprobe Energy Click to Download Applications Parts & Options Parts&Options Description Part Number Instrument Pyroprobe 5200 High Pressure Pyrolyzer with Thermal Desorption and Reactant Gas Operation 5004-5103(115V)/5004-5104(220V) Option Steam Option for 5200 HPR 5004-5115(115V)/5004-5116(220V) Option CDS Model 5500 Pyroprobe Fixed Gas Analyzer 5404-5013(115V)/5404-5014(220V) Option Eldex HPLC Pump for Steam Option 1010-0536 Option Heated Tubular Reactor Option 5004-5117(115V)/5004-5118(220V) Parts Sorbent Tube, 6 mm O.D. x 4 1/2" long, packed with 150 mg 60:80 mesh Tenax-TA MX06-2111 Downloads Downloads Marketing Brochures CDS Pyroprobe Brochure Request form for manuals and software Thanks for contacting CDS! Our specialist will contact you soon. Send Pyroprobe Series CDS 4000 CDS's most cost effective single temperature Pyroprobe. Read More CDS 6200 CDS's 6th Generation Pyroprobe with trapping capabilities for reactant gas apps. Read More DISC Module CDS's DISC module provides the easiest way to load your pyroloysis sample. Read More CDS 6150 CDS's 6th Generation Pyroprobe with up to 10 programmed temperature steps. Read More CDS 6400 CDS's 6th Generation Pyroprobe with up to 10 programmed temperature steps and large volume samples. Read More Autosampler Module CDS's autosampler module with Dynamic Loading to improve productivity for any 6000 series pyroprobe. Read More CDS HPR CDS's HPR Pyroprobe allows pyrolysis at elevated pressure with built-in reactor. Read More Photoprobe Photoprobe is a device that irradiates sample in the Drop In Sample Chamber with high intensity UV light Read More Cryo-mill CDS's cryo-mill is a laboratory ball mill that grinds polymer sample in liquid nitrogen temperature. Read More Microplastics Standards Mixed microplastics standards with options prepared according to ASTM Method 8401-24. Read More MSChrom Py-GC-MS Database Powerful Py-GC-MS data processing software and database Read More
- CDS Analytical | Pyrolyzer | DISC Module
CDS's DISC module provides the easiest way to load your pyroloysis sample. Home >> Products >> Pyrolysis >> DISC Module Pyrolysis Introduction Features Applications Parts & Options Downloads DISC Module Photo above showing DISC mounted on a 6150 Product Introduction Specifications: Temperature Range: Heating Rate: Interface Temerature: Compatibility : Weight: Dimension (W x H x D): Options: Programmable to 1300°C Programmable from 0.01°C/s to 20°C/s From ambient up to 300°C 6150, 6200 1.5 kg 4" X 5" X 3" Autosampler Photos above showing DISC mounted on a 6150 Summary The Drop-In-Sample-Chamber (DISC) is a novel accessory module for the 6000 series Pyroprobes. It transforms the horizontal sample loading probe used in traditional manual pyrolysis system to a convenient vertical loading system. The DISC saves your precious time by reducing the sample tube loading process. When used with the filler rod, the DISC helps to reduce sample preparation time by skipping the quartz wool insertion. The DISC chamber also isolates the pyrolysis sample tube from touching the platinum heating coil and can help to eliminate coil damages. Product Features CDS Resistively Heated Filament The DISC chamber adopts the same legendary CDS resistive heating coil to pyrolyze your sample with the lowest thermal mass and quickest temperature ramp up rate. Most Convenient Way to Load Pyrolysis Samples It has never been easier before to load a pyrolysis tube when using the DISC chamber, thanks to the novel design of the vertical loading method. Minimum Effort in Routine Maintenance The DISC chamber is designed with the user in mind, and requires minimum maintenance. An occasional septum change is all that is needed to keep it operating properly. Upgrade to Autosampler The DISC chamber is the core component of the autosampler module, and could be easily upgraded on site. Multi-point Calibration The DISC chamber is calibrated by NIST-traceable temperature probe on the sample temperature to within 0.1 °C. Software Compatible The 6000 series software has embeded the DISC control option for both 6150 and 6200. Product Introduction Product Features Applications 293 Characterizing Tar Products from Corn Stover in Gasification using the CDS 5200HPR This application note investigates PAH formation in untreated and demineralized corn stover using pyrolysis in air under elevated... 292 Screening Total Organic Fluorine in Solid Samples Using a Pyroprobe This application note highlights the use of the Pyroprobe 6150 for the analysis of Total Organic Fluorine (TOF), PFAS as a screening... 291 Rapid Characterization of a Solid Pipeline Residue from CO2 Capture Processes Using a Pyroprobe This application note highlights the use of the Pyroprobe 6150 for the analysis of a solid residue collected from CO2 capture systems,... 289 Characterizing a Lithium-Ion Battery Recycling Stream using Evolved Gas Analysis and Multi-Step Pyrolysis This application note investigates the lithium-ion battery recycling stream using Evolved Gas Analysis coupled with Multi-Step Pyrolysis... 288 Characterizing Textiles using Evolved Gas Analysis and an MSChrom Database This application note demonstrates characterization of woven jean fabric using Evolved Gas Analysis coupled with Multi-Step Pyrolysis... 282 Pyrolysis of HDPE Using Hydrogen as a GC Carrier Gas This application note demonstrates the benefits of using hydrogen as a carrier gas on a Thermo GC-MS and a CDS Pyroprobe. 6000 6200 6150 1 2 3 4 5 Applications Parts & Options Instruments Description SKU Standard in 6150 Pyroprobe Standard in 6200 Pyroprobe Please reload Options Description SKU There are no items in this list Please reload Parts Description SKU Quartz tubes for DISC (20/pack) 6201-3004 Quartz replacement Chamber for DISC 6203-5041 DISC top septum 2180-0019 DISC bottom septum 6201-3002 DISC spring 1010-0550 Please reload Parts & Options Downloads Marketing Brochures CDS Pyroprobe Brochure Request form for manuals and software Thanks for contacting CDS! Our specialist will contact you soon. Send Downloads Pyroprobe Series CDS 4000 CDS's most cost effective single temperature Pyroprobe. Read More CDS 6200 CDS's 6th Generation Pyroprobe with trapping capabilities for reactant gas apps. Read More DISC Module CDS's DISC module provides the easiest way to load your pyroloysis sample. Read More CDS 6150 CDS's 6th Generation Pyroprobe with up to 10 programmed temperature steps. Read More CDS 6400 CDS's 6th Generation Pyroprobe with up to 10 programmed temperature steps and large volume samples. Read More Autosampler Module CDS's autosampler module with Dynamic Loading to improve productivity for any 6000 series pyroprobe. Read More CDS HPR CDS's HPR Pyroprobe allows pyrolysis at elevated pressure with built-in reactor. Read More Photoprobe Photoprobe is a device that irradiates sample in the Drop In Sample Chamber with high intensity UV light Read More Cryo-mill CDS's cryo-mill is a laboratory ball mill that grinds polymer sample in liquid nitrogen temperature. Read More Microplastics Standards Mixed microplastics standards with options prepared according to ASTM Method 8401-24. Read More MSChrom Py-GC-MS Database Powerful Py-GC-MS data processing software and database Read More
Blog Posts (275)
- 296 Paint and Polymer Analysis using LabTech CDS Model 6400 Pyroprobe with Sample Splitting
This application note demonstrates using the splitting function of a Pyroprobe to adjust the sample amount transferred to the gas chromatograph. Plastics
- 295 Microplastic Calibration Using EasyPyCal™ Standards
This application note demonstrates the use of a Pyroprobe 6150 with a commercially available mixed microplastics standard to build microplastic calibration curves. Environmental Human Health and Safety
- 294 Performance Fabric Identification using Evolved Gas Analysis and Multi-step Pyrolysis GC-MS with MSChrom + CDS EGA and Py Databases
This application note demonstrates the use of a Pyroprobe 6150 to characterize an elastomeric fabric using Evolved Gas Analysis (EGA) plus Multi-Step Pyrolysis (MSP), along with CDS’s EGA and Pyrolysis Databases on Mestrelab’s Mnova MSChrom + DB and CDS plugins. 6 000 Evolved Gas Analysis Autosampler PY Library
Events (32)
- purge and trap webinarTickets: $0.00October 9, 2024 | 11:00 PM
- March 3, 2025 | 2:00 PM415 Summer St, Boston, MA 02210, USA
- October 9, 2024 | 11:00 PM










