top of page

Search Results

107 results found with an empty search

  • CDS Analytical | Nitrogen Concentrator | MV5

    10 position multi-channel nitrogen concentrator Home >> Products >> Nitrogen Concentrator >> M10 Nitrogen Concentrators Introduction Features Applications Parts & Options Downloads M10 Product Introduction Product Introduction Specifications: Control Panel Temperature Accuracy Temperature Control Temperature Range Independent Drying Channels Max sample positions Supported Test Tube (ml) Supported Cocentration Vial with Fixed End Point (ml) Infrared sensors Nitrogen requirement (psi) Dimensions (L×W×H) cm Weight (Kg) Touch Screen ±0.1°C P.I.D. Ambient to 100°C 10 10 None 50, 200 Yes 30-100 44x68x33 25 Summary The M10 Automatic Parallel Concentration System increases capacity and sample throughput in laboratories while maintaining quality at an economical price. With this system, users can evaporate off all solvents or concentrate into a fixed endpoint volume. The M10 Automated Concentrator is a compact solution compared to conventional rotary evaporators, with the possibility to be used outside fume hood, thanks to the integrated vapor exhausting system. The standard configuration comes with 10 of 200 mL concentration vials with 1 mL end point, 10 of 50 mL concentration vials with 1 mL end point, 1 1 of 10 position 50 mL rack, and 1 of 10 position 200 mL rack. Product Features High Throughput 10 channels able to Stop/start, add/remove samples at any time during evaporation process User Friendly Interface Full color touch screen control panel with easy navigation Mix and Match Supports mix and matching 50ml and 200 mL concentration cups Smart Evaporation Automatic detection of the liquid endpoint Visible Process The evaporation process is visible with front window Versatile Configuration Choose adapters to support concentration vials with different end point Product Features M10 Temperature Control Temperature Accuracy Sample Position Nitrogen Needle Concentration Cup Vacant Spot Detection Ambient to 99 °C Up to 70 °C for final volume ±1 °C 10 Adjustable 50 ml, 200 ml Yes Biotage Turbovap II Ambient to 99 °C Up to 60 °C for final volume ±2 °C 6 Fixed 50 ml , 200 ml Not Supported Applications Chemistry Environmental organic analysis Food Forensic medicine Geochemistry Organic analysis Organic analytical chemistry Petroleum analysis Applications Parts & Options Category Part Number Description Parts Y042704007 Vial Adaptor for 0.5ml end point including O ring Parts MT-BC200-10 10-position external bracket for 200ml cup Parts MT-BC50-10 10-position external bracket for 50ml cup Parts & Options Downloads Downloads Marketing Brochures Nitrogen Concentrator Brochure Request form for manuals Thanks for contacting CDS! Our specialist will contact you soon. Send Family Series MV5 54 sample position multi-channel parallel nitrogen concentrator Read More M10 10 sample position multi-channel parallel nitrogen concentrator for large volume samples Read More

  • Pyrolyzer | Thermal Desorber | Purge and Trap | 3M Empore

    CDS Analytical propvides Pyrolyzer for Pyrolysis - Gas Chromatography - Mass Spectrometry (Py-GC-MS), Thermal Desorber for Thermal Desorption - Gas Chromatography - MAss Spectrometry (TD-GC-MS) and Purge and Trap Concentrator for EPA 524, 624, 8260 methods in the analytical lab. CDS also manfuactures 3M Empore Solid Phase Extraction consumables. 7550S Pro Thermal Desorber 72-postion TD-GC-MS autosampler with automated sample saver Click Me Products Pyrolysis Thermal Desorption Purge and Trap Empore Water Chillers Water Chiller Digestion Blocks Digestion Blocks Vacuum Pumps Vacuum Pumps Hotplates Hotplates Rotary Evaporators Rotary Evaporators Nitrogen Concentrators Nitrogen Concentrators Events October 14-15, 2025 Gulf Coast Conference in Galveston, TX October 22-23, 2025 Northeastern Association of Forensic Scientists in Lancaster, PA Updates 293 Characterizing Tar Products from Corn Stover in Gasification using the CDS 5200HPR Feb 6 292 Screening Total Organic Fluorine in Solid Samples Using a Pyroprobe Dec 24, 2024

  • CDS Analytical | Rotary Evaporator | EV400

    2nd Generation rotary evaporator with motor lifting Home >> Products >> Chiller >> H150-1500 Water Chillers Introduction Features Applications Parts & Options Downloads H150-1500 Product Introduction Product Introduction Specifications: 8 - 35°C ± 0.1°C PID 1500W 6.4 L/min 120W Board water 65×39x63 68 115V, 60Hz Temp. Range Temp. Stability Temp. Control Mode Cooling Capacity @ 25°C Pump Flow Rate Pump Power Heat Exchange Mode Chiller Fluid Type Dimensions (L×W×H) cm Weight (kg) Power Supply Summary The LabTech H150-1500 water chiller is a versatile unit produced with durable, eco-friendly materials while delivering high performance with precise temperature control. The H150-1500 supports a touch screen for easy control with a liquid level indicator. With high efficiency and high performance, LabTech water chillers are a perfect fit to service analytical, medical, and industrial applications. Product Features Touchscreen Control Smart touchscreen interface for easy temperature adjustment between and 8 and 35 °C . Environmentally Friendly LabTech water chillers are environmental friendly utilizing a CFC-free coolant. High Energy Efficiency Hot gas bypass eliminates compressor on/off cycles to deliver a greener, more efficient performance. High Quality Components The high-quality condenser and compressor make LabTech water chillers durable and perfect for 24/7 use. Liquid Level Indicator Convenient liquid level indicator makes it easy to monitor the liquid level to maintain optimum chiller performance. High Quality Electronics LabTech water chillers meet the high standards for RoHS certification requiring all electronics components are free of hazardous materials, including heavy metals and phthalates. Product Features Temp. Range Temp. Stability Temp. Control Mode Cooling Capacity @ ambient Pump Flow Rate Refrigerant Tank Volume 8 - 35°C ± 0.1°C 1500W 6.4 L/min R134a 4 L H150-1500 F-105 -10 - 25°C ± 1.0°C 530W 2.3 L/min R134a 3 L Applications ICP (Perkin Elmer, Agilent, Thermo, Shimadzu) Atomic Absorption (Perkin Elmer, Agilent, Thermo, Shimadzu) Purge and Trap Rotary Evap oration Distillation Vacuum Systems Kjeldahl Digestions Applications Parts & Options Downloads Marketing Brochures Water Chiller Brochure Request form for manuals Thanks for contacting CDS! Our specialist will contact you soon. Send Downloads Family Series H50-500 Low temperature, CFC-free, energy efficient water chiller for small lab equipment. Read More H150-1000 CFC-free, energy efficient water chiller for medium-large lab instrumentation. Read More H150-1000LT Low temperature, CFC-free, energy efficient water chiller for medium-large lab instrumentation. Read More H150-1500 High power, CFC-free water chiller for large lab instrumentation. Read More

  • CDS Analytical | Thermal Desorber | 7550

    72 position autosampler for 9300 families improve productivity and efficiency.  Home >> Products >> Thermal Desorption >> CDS 7550 Thermal Desorption Introduction Features Applications Parts & Options Downloads CDS 7550 *Purge and Trap Tower shown in the photo is an optional configuration Product Introduction Product Introduction Specifications: TD Tube Positions: Tube Supported: Concentrator: Concentrator Connection: Internal Gas Addition: Sample Saver: Tube Heating Rate: Sample Desorb: Weight: Dimension (W x H x D): Options: 72 6mm x 4.5" and 1/4" x 3.5" CDS 7000E Required Heated Transfer Line (350°C) Yes, optional Yes, optional 1000°C/min Up to 400°C 23 kg 56.9cm X 48.2cm X 62.2 cm Purge and Trap Summary Operating on the 2nd generation autosampler, the CDS 7550 is capable of 3D positioning within 1 mm, and thanks to its unique user settable calibration, it could handle standard 3.5" Thermal Desorption tube from any manufacturer. These features make CDS 7550 the most reliable Thermal Desorption autosampler available to the market. The Internal Standard module and Sample Saver module are optional. The CDS 7550 Thermal Desorption Tower could be purchased separately and added to your existing 7450 system to expand the sample introduction capability from Purge and Trap to Thermal Desorption. The switch process is engineered to be effortless. Product Features 72 Position Autosampler CDS adopts a novel way to protect the TD tube by sealing in a reusable gas tight metal chamber, while waiting for the autosampler to pick up. Excellent TD Tube Compatibility The autosampler can be configured through a calibration program to take standard 1/4" X 3.5" stainless steel TD tube from any manufacturer. Precision Robotic Arm The robotic arm holds 1mm X,Y,Z accuracy. The reliable gripping mechanism has the capability to handle both Pyrex glass and stainless steel TD tubes. Optional Sample Saver The optional sample saver module enables the sample to be re-adsorbed back to the tested TD tube. Optional Gas IS Module The optional IS module helps to obtain consistent response factor in GC/MS runs. Built-in Leak Check The automated leak check assures the system is air-tight before proceeding with the desorption of your sample. Product Features Applications 267 Quantification of Limonene from Essential Oil Emissions using Thermal Desorption GC-MS Analysis This application note demonstrates a method for sampling and analyzing volatile organic compound (VOC) emissions of essential oils using... 258 Thermal Desorption Analysis of Essential Oil Emissions from Common In-Home Diffusers This application note demonstrates a method for sampling and analyzing VOC emissions of essential oils from in-home diffusers. As part of... 257 Thermal Desorption Analysis of Asphalt Binder Samples Contaminated with Automotive Fluids This application note demonstrates a method for using thermal desorption as a way to screen asphalt binder samples for the presence... 248 Automated TD Sample Preparation of Calibration Standards This application note demonstrates quantitative sample preparation of calibration standards using the CDS 7550S automated thermal... 243 Sample Recollection by the CDS 7550S Automated Thermal Desorber Quantitative recollection of split sample to a clean sample saver tube, demonstrated by different split percents on the CDS 7550S... 241 Determination of VOCs in Air by Adsorption Tube Sampling-Thermal Desorption GC-MS (HJ 644-2013) This application note demonstrates the superior performance of CDS Analytical's automatic electronic cooling and thermal desorption... 1 2 Applications Parts&Options Description Part Number Instrument CDS 7550 Thermal Desorption Autosampler (3.5" Tube) - 7000E or 9300 concentrator needs to be purchased separately 7554-5007(115V)/7554-5008(220V) Option Single Tube Conditioner - Model 10 TC01-1000 Option 7550 Sample Saver with re-collection Option 7503-5017 Option Single Tube Conditioner - Model 10 TC01-1000 Option Single Channel Air Sampler 1010-0573 Option Gas Internal Standard Addition Option for 7550/7550S 7503-5010 Parts 1/8" SS Trap, Vocarb - 4 1/2" Long 9301-5055 Parts 1/4" x 3.5" Thermal Desorption Tube, Tenax TA 60/80 C-SIC60520-60-B Parts 1/4" x 3.5" Thermal Desorption Tube for PAH C-SIC60564-B Parts 7550/7550S Top Tube Seal Septum with Hole 7503-1001 Parts 1/8" SS Trap, packed with Glass Beads 60:80 mesh - 4 1/2" Long 9301-5076 Parts 1/8" SS Trap, packed with Tenax - TA 60:80 mesh - 4 1/2" Long 9301-5056 Parts 1/4" x 3.5" Thermal Desorption Tube for EPA Method 325 C-SIC60524-B Parts 7550/7550S Left Gripper 7502-5041 Parts Valve Rotor for Stright 8 Port Valve 2460-0247 Parts 1/4" x 3.5" Thermal Desorption Tube, Carbograph2 / Carbograph1 / Carboxen 1000 SU644-4 Parts 1/4" x 3.5" Thermal Desorption Tube for Emissions C-SIC60567-B Parts 1/4"x3.5" Thermal Desorption Tube, Unconditioned, and Tenax TA 60:80 SU60520-60 Parts 7550/7550S Right Gripper 7502-5042 Parts Kalrez o-ring, bottom tube heater seal 1620-0493 Parts & Options Downloads Downloads Marketing Brochures CDS Thermal Desorption Brochure Request form for manuals and software Thanks for contacting CDS! Our specialist will contact you soon. Send Thermal Desorption Series CDS 9300 CDS's base model instrument for single tube desorption. Read More CDS 9350 CDS 9350 supports continuous real time air monitoring through a dual tube setup. Read More CDS 7550S Stand-alone 72 position Thermal Desorption system Read More Sampling Devices Portable single channel air sampler Read More CDS 9305 Near-real time sampling Thermal Desorption system. Read More CDS 7550 72 position autosampler for 9300 family improve productivity and efficiency. Read More Tube Conditioner CDS's single and six tube conditioners are essential accessories for your analysis. Read More CDS 7550S Pro Stand-alone 72 position Thermal Desorption system with automated sample saver Read More

  • Environmental Measurement Symposium (EMS) 2024 | cdsanalytical

    Mon, Aug 05 | Garden Grove Environmental Measurement Symposium (EMS) 2024 Introducing the 3rd Gen Automated Thermal Desorber 7550S Registration is closed See other events Time & Location Aug 05, 2024, 10:00 AM – Aug 07, 2024, 3:00 PM Garden Grove, 11999 Harbor Blvd, Garden Grove, CA 92840, USA About the event EMS is the combined meeting of the National Environmental Measurement Conference (NEMC) and the Forum on Environmental Accreditation with a focus specifically on environmental measurements. Please join us for a chat on your applications on GC front end sample introduction as well as SPE. CDS is launching its 3rd generation automated Thermal Desorption concentrator 7550S Pro in this show. Show More Share this event

  • CDS Analytical | Applications

    Home >> Applications Applications Recent Posts 284 Rapid Characterization of Seized Street Drugs using Evolved Gas Analysis plus Multi-Step Pyrolysis 282 Pyrolysis of HDPE Using Hydrogen as a GC Carrier Gas 283 Deconvolution of Plastic Mixtures using a Polymer Subtraction Function in Py-GC-MS Data Analysis Software 281 Enhancing Characterization of Mixed Polymers with a Mass Spectral Processing Software for Py-GC-MS 204 Complete Polymer Analysis using the Pyroprobe 6000 Seriescoupled with MS and GC-MS Search By Market Adhesive (23) 23 posts Aerospace (4) 4 posts Agriculture (16) 16 posts Automobile (20) 20 posts Biochemical (1) 1 post Chemical Weapon (3) 3 posts Cosmetics (15) 15 posts Energy (20) 20 posts Environmental (106) 106 posts Food and Flavor (46) 46 posts Forensics (15) 15 posts Fragrance (16) 16 posts Homeland Security (5) 5 posts Paint (18) 18 posts Paper & Ink (12) 12 posts Pharmaceuticals (17) 17 posts Plastics (59) 59 posts Pyrolysis Theory (9) 9 posts Rubber (17) 17 posts Semiconductor (5) 5 posts Textiles (15) 15 posts Tobacco (6) 6 posts Electronics (5) 5 posts General Interest (19) 19 posts Cannabis (7) 7 posts UV Degradation (4) 4 posts Human Health and Safety (10) 10 posts Military (5) 5 posts Explosives (1) 1 post customer testimonials (0) 0 posts Life Science (4) 4 posts Proteomics (3) 3 posts Plastics Recycling (1) 1 post General (3) 3 posts Search By Instruments 5200HPR 5500 Fixed Gas Analyzer 6000 6150 6200 7000 7000C 7300 7400 7450 7500 7550S 8000 8500 Autosampler cryo-mill Deconvolution AMDIS DHS Dynamic Headspace Dynatherm Dynatherm 9350 E3technology EGA EGA- Evolved Gas Analysis Empore Empore C18 Cartridge Empore Disk EZTrace Forensic Science Heartcut High Pressure High Pressure Reactor Hydrogen LC-MS/MS Life Science microplastics multi-step Multi-step multiple ramp P&T PAL Photoprobe Proteomics Purge & Trap Py GCxGC MS PY Library Py-GC HR-TOF Py-GCxGC-HRMS pyrolysis Pyrolysis Pyrolysis FTIR Pyrolysis MS pyroprobe Pyroprobe Pyrotomy quickramp Reactant Gas Reactor RoHS SampleSaver SPE Spin column StageTips Steam Steam HP TD Thermal Desorption Thermal Extraction Thermal Slice thermaldesorption tubedesorber Jun 7 284 Rapid Characterization of Seized Street Drugs using Evolved Gas Analysis plus Multi-Step Pyrolysis This application note demonstrates a fast Py-GC-MS testing method for seized street drugs Pyroprobe 6000 6150 Multi-step EGA- Evolved Gas... Apr 19 282 Pyrolysis of HDPE Using Hydrogen as a GC Carrier Gas This application note demonstrates the benefits of using hydrogen as a carrier gas on a Thermo GC-MS and a CDS Pyroprobe. 6000 6200 6150 Apr 12 283 Deconvolution of Plastic Mixtures using a Polymer Subtraction Function in Py-GC-MS Data Analysis Software This application note demonstrates a polymer subtraction capability in Py-GC-MS data analysis software. Pyrolysis PY Library General Apr 5 281 Enhancing Characterization of Mixed Polymers with a Mass Spectral Processing Software for Py-GC-MS This application note demonstrates a polymer subtraction capability in py-gc-ms data analysis software. PY Library Mar 18 204 Complete Polymer Analysis using the Pyroprobe 6000 Seriescoupled with MS and GC-MS The latest version of the Pyroprobe from CDS Analytical includes easier sample preparation and introduction with the new DISC (Drop In... Jan 18 280 Characterizing Waste Plastic Pyrolysis Oils using a Pyrolysis GC-MS This application note demonstrates characterization of “ugly” plastic pyrolysis oils using Evolved Gas Analysis coupled with Multi-Step... Dec 15, 2023 279 Applying Empore™ E3technology™ to Proteomic Sample Preparation This note describes several applications of E3technology™ for proteomic sample preparation, which include two major components, protein... 1 2 3 4 5

  • 404 | cdsanalytical

    There’s Nothing Here... We can’t find the page you’re looking for. Check the URL, or head back home. Go Home

bottom of page